I/A SCADA - TOP CLASS performance & availability for all Industries
Very High reliability and performance (Solaris 10 Servers, Windows XP Engineering and Operations)
Optimized for use in Pipelines management, Electric and Municipal applications
Distributed object-oriented Databases and Operations
Enhanced and prompt DISASTER RECOVERY capability
Multiple redundancy levels
Web enabled
RTU20 - General Purpose for ALL Industries TOP Modularity & Redundancy
-
Oil & Gas Pipelines, Water & Wastewater, Electric power, District heating and Municipal Multi-Service Utility applications
-
Industrial 32-bit CPU - 4 Serial communication lines RS232 or RS485
-
Multiple Protocols : DNP3, MODBUS, P6008 - Master/Slave RTUs connections
-
Very modular configuration and expandability: from few to several hundreds of I/O points
-
Redundant CPU, Power supply and Communication I/F modules for high availability applications
-
IEC 61131-3 “Local automatic sequences” configuration
-
Store & Forward, Report-by-Exception, Unsolicited and Spontaneous-call communications
-
Sequence of Events up to 1 ms. resolution
-
PID algorithms & Flow Calculation (AGA3, AGA5, AGA7, AGA8, NX19)
-
Very low Power consumption : typical 6 Watts
-
Operating temperature from -25 to +70 Deg C
RTU50 - FIRST CLASS Data Concentrator and Communicator
-
Distributed Electric substations Automation and Pipeline Data concentrator
-
High performance industrial 32-bit CPU
-
Multiple protocols : DNP3, IEC 60870-5-101, IEC 60870-5-103, MODBUS, Conitel C2020/C2025/C300/C3000, Harris 5000/5500/6000, WISP+, etc.
-
Communication interfaces: V.11 (RS422/485), V.23, V.28 (RS232), Optical fiber serial interfaces, 10BaseFL TCP/IP & UDP/IP network interfaces
-
-
Flow Calculation : AGA3 (Orifice), AGA7 (Turbine), Super-compressibility Calculation (NX19)
-
Substation Automation functions: Transformer synchronization, Capacitor bank switching, Circuit breaker re-closure, Automatic load shedding, Power calculations (V, A, VA, VAR, PF), IED interfacing (protection relay, power meters, etc.), SOE 1 msec. resolution and data logging
-
Transducerless 3 phase CT-PT inputs
-
Scalable : 4 to over 45000 physical I/O, through "OptoNet” optic-fiber networking, virtual I/O up to 90000 points per OptoNet node
-
IEC 61131-3 & SALL local sequences configuration
-
Local Data Archiving, Processing, Calculation, Regulatory Control
SCD5200 - Station Computing Device : the RTU's "Evolution"
-
Fits a wide range of Electric Power and Oil and Gas applications
-
IEC61850 Client Conformance
-
High performance industrial 32-bit CPU, Power Supply, OptoNet and Dual Channel Ethernet on a single card
-
Real Time Operating System
-
Available in 3 standard sizes: 1 -2- 5 - 10 I/O slot chassis
-
Multiple Protocols : DNP3, IEC 60870-5-101, IEC 60870-5-103, MODBUS, Conitel C2020/C2025/C300/C3000
-
Communication interfaces: V.11 (RS422/485), V.23, V.28 (RS232), Optical fiber serial interfaces, 10BaseFL TCP/IP & UDP/IP network interfaces
-
Powerful, scalable distributed configuration supports very large applications, up to 22500 physical I/O points or over five million virtual I/O points
-
IEC 61131-3 and SALL application programming for local sequences
-
1ms Resolution for Sequence of Events
-
Substation Automation functions: Transformer synchronization, Capacitor bank switching, Circuit breaker re-closure, Automatic load shedding, Power calculations (V, A, VA, VAR, PF), IED interfacing (protection relay, power meters, etc.), SOE 1 msec. resolution and data logging
-
Transducerless 3 phase CT-PT inputs
-
File System
-
Wide range 18 to 164V DC power input
-
Operating temperature from -40 to +70 Deg C (-40 to +158 Deg F)
|
Related Products
|