Invensys Process Systems
Performance Applications 

Improve Operator & Engineer Efficiency. 

The I/A Series Mesh network means increased performance, reliability, & capacity for your system. It also means better diagnostic tools to help you run your plant more efficiently. Our performance applications provide root cause analysis so you can easily & efficiently prevent & address process issues should they arise.

Message Manager. Our Message Manager package provides a configurable capability to reprioritize alarms based on changes in operating conditions. Operator overload is eliminated with automatic alarm shower detection & suppression, allowing you to focus on what is most important.  If you understand the problem, you can fix the problem.

  • Alarm shower detection & avoidance
  • Configure alarms based on plant mode – startup, normal operation, shutdown
  • Configure alarms to be reprioritized, inhibited or disabled based on plant mode or trip event
  • Plant-wide synchronization of alarms
  • Software Redundancy – no single point of failure, & no loss of data
  • Automatic operator notification – voice message, email, or printed message

Transient Data Recorder & Analyzer . Our Transient Data Recorder & Analyzer (TDR/TDA) is an intuitive configurable software package for transient data collection & analysis of process variables to help you easily understand process conditions leading up to & post a process event or trigger. TDR/TDA is a powerful troubleshooting tool; making corrective action simple now knowing what caused the event.

  • Plant-wide capture and analysis of high speed digital(1ms) & analog(10ms ) data.
  • Comprehensive set of configurable displays, logs & reports.
  • Time stamping done at the I/O level for improved accuracy in reporting.
  • User defined trip conditions possible.
  • 20 minutes of pre and post event data stored.
  • Easy to use standard Microsoft Windows Graphical User Interface look &feel. 

Sequence of Events.  Our Sequence of Events (SOE) package is easy to use configurable software for high resolution acquisition, storage, display, & reporting of binary events & disturbances in the plant. This package allows you to capture & analyze plant-wide high frequency digital data for post mortem analysis & determine what happened first in a plant trip sequence, & quickly take corrective action. If you understand the issue, you can fix the problem.

  • Time stamping done at the I/O level (1ms resolution).
  • Rich set of pre-configured set-up, logs & reports.
  • Plant-wide synchronization, with data viewable from any workstation.
  • Full compliance with government regulations.
  • Pinpoint the problem – what happened first?